<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Case Studies &#8211; AI-Gruppe</title>
	<atom:link href="https://gruppe.ai/category/case-studies/feed/" rel="self" type="application/rss+xml" />
	<link>https://gruppe.ai</link>
	<description>Immer eine zündende Idee!</description>
	<lastBuildDate>Thu, 06 Jun 2024 11:13:56 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.3</generator>

<image>
	<url>https://gruppe.ai/wp-content/uploads/2022/08/cropped-faviconai-32x32.png</url>
	<title>Case Studies &#8211; AI-Gruppe</title>
	<link>https://gruppe.ai</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Pumpenüberwachung RAG</title>
		<link>https://gruppe.ai/2024/06/06/pumpenueberwachung-rag/</link>
					<comments>https://gruppe.ai/2024/06/06/pumpenueberwachung-rag/#respond</comments>
		
		<dc:creator><![CDATA[Tobias Kestin]]></dc:creator>
		<pubDate>Thu, 06 Jun 2024 07:55:13 +0000</pubDate>
				<category><![CDATA[Case Studies]]></category>
		<guid isPermaLink="false">https://gruppe.ai/?p=1487</guid>

					<description><![CDATA[Um die Vermischung von Trinkwasser und Grubenwasser zu vermeiden, pumpt die RAG Grubenwässer ab, reinigt diese und führt sie dem Rhein bzw. der Ruhr zu. Hierzu setzt die RAG rund ein Dutzend Grubenwasserpumpen mit Leistungen im Megawatt-Bereich ein. Eine Wartung der in bis zu 3 km Tiefe versenkten Pumpen geht mit großem Zeit- und Planungsaufwand einher.]]></description>
										<content:encoded><![CDATA[
<h2 class="erste">Problemstellung</h2>



<p><b>Um die Vermischung von Trinkwasser und Grubenwasser zu vermeiden, pumpt die RAG Grubenwässer ab, reinigt diese und führt sie dem Rhein bzw. der Ruhr zu. Hierzu setzt die RAG rund ein Dutzend Grubenwasserpumpen mit Leistungen im Megawatt-Bereich ein. Eine Wartung der in bis zu 3 km Tiefe versenkten Pumpen geht mit großem Zeit- und Planungsaufwand einher. Ziel des Projektes war es, zu evaluieren, ob Motorstromsignatur-Analysen dabei unterstützen können, Wartungszyklen zu verlängern. Dazu wurde experimentell die Grubenwasserpumpe am Schacht
Friedlicher Nachbar untersucht.</b></p>



<h2 class="wp-block-heading">Lösungsansatz</h2>



<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:66.66%">
<p>Eine Beobachtung der von der Pumpe aufgenommenen Leistung stellt eine repräsentative Messung für die Qualität des Motorlaufes dar. Eine besondere Schwierigkeit im vorliegenden Fall ergibt sich aus den hohen Spannungen und Strömen, welche besondere Messtechnik notwendig machen. Hierzu wurde ein Konzept entwickelt, welches eine nachträgliche Synchronisation unterschiedlicher Messgeräte ermöglicht.</p>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:33.33%">
<figure class="wp-block-image size-large"><img fetchpriority="high" decoding="async" width="766" height="1024" src="https://gruppe.ai/wp-content/uploads/2024/06/RAG-766x1024.jpg" alt="" class="wp-image-1488" srcset="https://gruppe.ai/wp-content/uploads/2024/06/RAG-766x1024.jpg 766w, https://gruppe.ai/wp-content/uploads/2024/06/RAG-225x300.jpg 225w, https://gruppe.ai/wp-content/uploads/2024/06/RAG-768x1026.jpg 768w, https://gruppe.ai/wp-content/uploads/2024/06/RAG.jpg 958w" sizes="(max-width: 766px) 100vw, 766px" /></figure>
</div>
</div>



<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<figure class="wp-block-image size-large"><img decoding="async" width="1024" height="687" src="https://gruppe.ai/wp-content/uploads/2024/06/Konfig1-1024x687.png" alt="" class="wp-image-1496" srcset="https://gruppe.ai/wp-content/uploads/2024/06/Konfig1-1024x687.png 1024w, https://gruppe.ai/wp-content/uploads/2024/06/Konfig1-300x201.png 300w, https://gruppe.ai/wp-content/uploads/2024/06/Konfig1-768x515.png 768w, https://gruppe.ai/wp-content/uploads/2024/06/Konfig1.png 1118w" sizes="(max-width: 1024px) 100vw, 1024px" /></figure>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow">
<h2 class="wp-block-heading">Implementierung</h2>



<p>Wie hier graphisch dargestellt, wurden zwei USB-Geräte genutzt, um experimentelle Daten aufzuzeichnen.<br>Dabei kam ein Labor-Spannungs-Digitizer der Firma Pico-Technologies zum Einsatz, um mit Hilfe von 1.000/1 Spannungsteilern die 10kV Versorgungsspannung der Pumpen zu monitoren, sowie drei Rogowski-Spulen, welche über eigens hierfür entwickelte Verstärkerschaltungen mit Auto-Intern OmnnI-Scopes aufgezeichnet wurden.<br>Die Datenauswertung fand im weiteren Verlauf im Büro statt.</p>
</div>
</div>



<div class="wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex">
<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:66.66%">
<h2 class="wp-block-heading">Ergebnisse</h2>



<p>Sogar bei den hohen Strömen und Spannungen der Grubenwasserpumpen konnten Vibrationen der Pumpe und nicht-sinusförmige Anregungen direkt gemessen werden. <br>Die dargestellte DQ-Transformation zeigt die Asymmetrie des verwendeten Motors. <br>Es konnte der Beweis erbracht werden, dass die Qualität des Motorrundlaufs mit Hilfe von Auto-Intern Messtechnik evaluiert werden kann.<br>Das Projekt befindet sich in der Planungsphase für eine Fortführung mit mehreren Pumpen.</p>
</div>



<div class="wp-block-column is-layout-flow wp-block-column-is-layout-flow" style="flex-basis:33.33%">
<figure class="wp-block-image size-full"><img decoding="async" width="700" height="700" src="https://gruppe.ai/wp-content/uploads/2024/06/DQ_Normalbetrieb_1.png" alt="" class="wp-image-1498" srcset="https://gruppe.ai/wp-content/uploads/2024/06/DQ_Normalbetrieb_1.png 700w, https://gruppe.ai/wp-content/uploads/2024/06/DQ_Normalbetrieb_1-300x300.png 300w, https://gruppe.ai/wp-content/uploads/2024/06/DQ_Normalbetrieb_1-150x150.png 150w, https://gruppe.ai/wp-content/uploads/2024/06/DQ_Normalbetrieb_1-600x600.png 600w" sizes="(max-width: 700px) 100vw, 700px" /></figure>
</div>
</div>



<p>Die hier dargelegte Case-Study ist Eigentum der Auto-Intern GmbH.<br>Alle enthaltenen Informationen sind zur Veröffentlichung der jeweiligen Kunden freigegeben worden.<br>Bei Fragen zum Inhalt wenden Sie sich an Herrn Stephan Bökelmann &#8211; <a href="mailto:sb@gruppe.ai">sb@gruppe.ai</a></p>
]]></content:encoded>
					